Abstract
The purpose of this study is to explore the numerical behavior of circular RC short columns with different degrees of confinement with CFRP (0%, 25%, 50%, and 100%) wraps under concentric and eccentric loading. The numerical analysis carried out by using an improved concrete plastic-damage model (CDPM) implemented in ABAQUS software for finite element (FE) analysis. The FE model simulated a total of twenty-four numerical specimens. The findings were matched to published experimental test results in the literature. The findings of the FE model and the experimental data were good similar. As a consequence, the model was found to be valid. The numerical results shows that as load eccentricity increased, the load carrying capacity of columns decreased for unconfined specimens, whereas the decline in strength for confined specimens becomes limited as the degrees of confinement ratio increased. In addition, increasing the CFRP confinement ratio improves the column's load-bearing capability at the same load eccentricity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.