Abstract
Numerical analysis of fin effect in heat exchangers used in split air conditioners
Highlights
In this study, heat exchangers in split air conditioners which are one of the most used air conditioning system applications in our daily life are chosen as a subject
Air velocity, pressure, and temperature variations are investigated by studying the effects of design parameters of a fin and tube heat exchanger on Nusselt number, convection heat transfer coefficient as well as heat transfer rates
It is found that the pipe diameter, the spacing between pipes and fins has a significant influence on variations of velocity, pressure, and temperature of the system, whereas effects of thicknesses of pipe and fins are not
Summary
Düz kanat borulu ısı değiştiricisi modeli ele alınmıştır. Şekil 1’de tez çalışmasında kullanılacak olan ısı değiştiricisinin modeli gösterilmektedir [13]. Şekil 4’te geometri üzerindeki gerekli olan sınır şartları oluşturulmuş olup bunların hangi yüzeylere ait olduğu gösterilmektedir. Şekil 2’de ilgili ısı değiştiricisinin geometrik kanat ölçüleri belirtilmektedir. Şekil 3’te kanat geometrisinin parametrelere bağlantısı gösterilmektedir. 2.2 Sınır şartları Oluşturulan sınır bölgeleri kanat geometrisi üzerinde tanımlanmış olup geometri üzerindeki sınır şartları, yapılan bütün analizlerde aynı kullanılmıştır. Tk1 = 333K ∆k= 0.13 mm qk1 = 0W/m3 Kanat 2 bölgesi (E): Kanat 2; sabit, sürtünmesiz yüzey. Tk2 = 333K ∆k= 0.13 mm qk2 = 0W/m3 Boru bölgesi (F): Borular; sabit, sürtünmesiz yüzey. Şekil 5’te oluşturulmuş ağ yapısı modeli gösterilmektedir. Kanatçıklar arası ve boru yüzeyi ağ yapısı görülmektedir. Şekil 6’da oluşturulmuş olan ağ yapısına ait skewness dağılımı grafiksel olarak belirtilmektedir.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have