Abstract
Phase change (PC) process and convection inside an open cavity equipped with two different PCMs are analyzed with the finite volume method with ANSYS Fluent. The analysis is conducted for three different Grashof number (Gr) values for fully and partly open configurations. It is observed that the PC becomes fast when the object is closer to the exit for the fully open case. The partly open case results in higher thermal performance improvements while the average Nusselt number (Nu) increment is 94.5% for PCM-18. PC and heat transfer characteristics are influenced by both material and location of the PCM. At Gr = 3.79 × 108, the average Nu rises by about 50% when PCM-22 is used instead of PCM-18. Location and type of PCM provide excellent tool for controlling the phase transition and heat transfer dynamics with a fully and or partly open cavity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.