Abstract
Built up box section is a doubly symmetrical section in which two C-channel connected at the flange using self-drilling screw. They are generally used in the construction industry to obtain higher rigidity, when a single section is not sufficient. Despite being widely used in the construction industry, there are limited studies on built-up box section. Moreover, the current design code does not provide clear design guideline for the calculation of built-up box section. Therefore, research on the built-up box section is important. This paper presents a finite element model to predict the compressive strength and simulate the behavior of cold-formed steel built-up box section. The finite element model was developed using ABAQUS CAE/6.14. Comparison of the finite element and experimental results showed good correlation. The model well predicted the behavior of the built-up box column.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of International Structural Engineering and Construction
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.