Abstract

Analyze the change of oil temperature flow times during the heating process of wreck heavy oil and the temperature gradient change in the radiation area of the heating source. Using the result guide the heating process of low-temperature underwater oil recovery operations on the wreck. fluid software was used for the analysis process of the numerical simulation, and the physical model test is a simulation test of low temperature underwater electromagnetic heating of heavy oil. In this way, data related to the heating process of heavy oil can be obtained. from the numerical analysis results and the physical model test results, it can be concluded that the numerical simulation results are similar to the experimental verification results. The result can be used for engineering guidance. Due to the physical properties of heavy oil, the oil temperature decays faster during the heating process and the radiation effect of heat source is small, using the electromagnetic heater heats the heavy oil in the oil tank, and the heavy oil can be heated to meet the requirements of the pumping operation in a short time. The calculation model parameters are derived from actual operations. Numerical calculations and physical test results are of great significance to engineering guidance and can guide the underwater cryogenic oil pumping operation of shipwrecks.