Abstract

BackgroundShoulder arthroscopy is the standard technique for performing procedures involving the intertubercular groove. Current techniques continue to produce excessive soft tissue manipulation and neurovascular injury. Materials and methodsA cross-sectional, observational and descriptive study was conducted on a cohort of 24 shoulders following the standard surgical protocol and using punch dissection. The neurovascular structures with risk of damage by the standard lateral portal were evaluated during the study to establish a secure area for a new arthroscopic portal. Finally, the safety of the new proposed site was evaluated. ResultsThe presence of 24 venous structures, with a mean diameter was 1.05mm (SD: 0.71) was documented. A tendency was observed in locating these structures in the lower half of the dissecting field for the left shoulders and a hypovascular area between the 7 and 10hours circle dissected relative to the right shoulder. The new site was determined at a point 1.5 cm anterolateral to the anterolateral border of the acromion at an angle of 60° degrees to the horizontal axis of the acromion and towards the intertubercular groove of the humerus. ConclusionsThe methodology used in this study is innovative, reproducible and applicable for the study of all existing shoulder arthroscopic portals procedures, as well as any joint. The results provided by this study will be helpful for clinicians to improve tenotomy/tendon tenodesis procedures of the long head of the biceps brachii tendon.