Abstract

The nucleate pool boiling heat transfer data on a smooth flat surface were measured for three binary mixtures of HC600a/HFC134a, HC600a/HC290, and HC600a/HFC23. Much effort was made to investigate the influence of the boiling range on the pool-boiling heat transfer performance. From the experimental results, the HC600a/HFC23 mixture with a wide boiling range showed lower heat transfer coefficients (HTCs) than the mixture with a narrow boiling range such as HC600a/HFC134a and HC600a/HC290 systems. The measured data were also compared with the results predicted by five well-known correlations. It can be found that the average deviation is less than 25% for mixtures with narrow boiling ranges, but a larger deviation for mixtures with wide boiling ranges.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.