Abstract

Because prestressed concrete containment vessel (PCCV) is the last barrier of nuclear power plant (NPP), Brillouin Optical Time Domain Analysis (BOTDA) was used in monitoring PCCV structure. However, the layout of distributed optic fiber sensors was not ideal so that the elongation of optic fiber sensors wasn’t uniform. If the monitoring data of a certain time was chosen as a standard, the result of strain variation would have a lot of disturbance points. Facing this problem, Kalman filter was used in data processing. Through Kalman filter, the results were smoother and the disturbance points were eliminated so that the manual work was decreased. As a result, Kalman filter is very useful in BOTDA data processing in the PCCV monitoring.