Abstract
Abstract This article presents a comprehensive evaluation of two nuclear-rated bilateral telerobotic systems, Telbot and Dexter, focusing on critical performance metrics such as effort transparency, stiffness, and backdrivability. Despite the absence of standardized evaluation methodologies for these systems, this study identifies key gaps by experimentally assessing the quantitative performance of both systems under controlled conditions. The results reveal that Telbot exhibits higher stiffness, but at the cost of greater effort transmission, whereas Dexter offers smoother backdrivability. Furthermore, positional discrepancies were observed during the tests, particularly in nonlinear positional displacements. These findings highlight the need for standardized evaluation methods, contributing to the development, manufacturing, and procurement processes of future bilateral telerobotic systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.