The resistance of NTC thermistors is decrease with the increase of temperature,and they generally have nonlinear resistance(R)-temperature(T) behavior.In practice,such thermistor sensor needs to be individually calibrated over the operating temperature range to ascertain the R-T characteristics.The MF501 thermistor applied in spacecraft thermal test was illustrated in this paper to introduce a simple and effective calibration and data processing method.The fitting residual,average error and function transfer error were selected to assess the adequateness of the method.The result showed that the calibration error could be controlled within 0.45 ℃ based on three-point calibration over the operating temperature range and the precision was fully satisfied.Calibration precision could be improved with increasing the calculated calibration points.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.