Abstract

To the Editor, With more widespread availability of portable ultrasound (US) equipment, there has been an increase in the use of US for arterial and venous cannulation. Though challenged by some, the use of US guidance for arterial cannulation has been reported to increase the rate of success, reduce the time required for placement, and decrease the rate of complications. Despite the potential benefits of US to guide radial artery cannulation, it is often reserved only for difficult situations when palpation or Doppler methods are unsuccessful. In certain circumstances, even US guidance may prove to be difficult secondary to hypotension, hypovolemia, vasospasm, peripheral vascular disease, as well as user inexperience. The initial assessment of the site for radial arterial cannulation is usually performed by placing an US probe perpendicular to the direction of the artery about 2-3 cm proximal to the distal wrist crease (Figure A). This should reveal a short-axis view of the radial artery (Figure B). Identification of the artery can be confirmed by gently increasing the pressure of the US probe over the artery and evaluating the compressibility of the visualized structures—i.e., the relatively noncompressible artery can be identified often flanked by highly compressible radial veins. Additionally, longitudinal imaging utilizing colour flow Doppler can ascertain the pulsatility and direction of blood flow. Furthermore, if needed, the US probe can be moved more proximally along the radial artery to identify a more optimal site for cannulation. Herein, we report several novel techniques to increase radial artery diameter by amplifying the characteristics of blood flow through the artery. This may be helpful during situations when conventional methods for cannulation have proven unsuccessful. The first of the techniques involves holding the US probe between the index and middle finger and placing it over the radial artery. By utilizing the index finger to apply pressure, the radial artery is occluded distal to the probe leaving space to perform arterial cannulation (Figure C). A short-axis US view of the radial artery is obtained, and an increase in the size of the lumen can be observed due to the distal outflow obstruction (i.e., from the digital pressure). This leads to an increase in back pressure and subsequent enlargement of the diameter and cross-sectional area of the radial artery (Figure D). Theoretically, the increase in the size of the artery when utilizing this technique may improve the cannulation success rate, reduce the time to cannulation, and possibly even lessen the complications of radial arterial cannulation due to a reduction in the number of cannulation attempts. The second proposed technique involves compression of the ulnar artery (by an assistant) at approximately 1-2 cm proximal to the distal wrist crease (Figure E). The occlusion of the ulnar artery may improve the blood flow through the radial artery and, as a result, increase the radial artery diameter and area (Figure F). The contribution of the occlusion of the ulnar artery to improve the radial arterial blood flow may be less than expected in patients with a positive Allen’s test. Theoretically, combining the above two techniques could further enhance the radial artery diameter. Future study might elaborate on the usefulness of these techniques to improve cannulation success rates. P. Maheshwari, MD (&) B. Kelsheimer, MD P. Maheshwari, MD Department of Anesthesiology, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA e-mail: Praveen-Maheshwari@ouhsc.edu

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call