Abstract
Achieving a good seal for the application of the vacuum-assisted closure (VAC) system in complex head and neck wounds is difficult. A case series of 4 patients who developed postoperative orocutaneous or pharyngocutaneous fistulas were studied. A sterile green glove was used as a sealant together with the VAC system. With utilization of a green glove, a good seal for the VAC system was obtained. This gave ample time to cleanse the wound and allow granulation tissue to form before proceeding on to the next stage of treatment. A green glove technique allows for a good seal for the VAC system to work, especially when applied to complex head and neck wounds. © 2016 Wiley Periodicals, Inc. Head Neck 38: E2523-E2526, 2016.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.