Abstract

Abstract High energy consumption during solvent regeneration is a crucial issue for the CO 2 post-combustion capture by chemical absorption. In order to save the latent heat in the regeneration process, it is possible to regenerate the solvent through direct steam stripping. This work aims to validate the direct steam stripping process by experimental study on a lab-scale stripper column. The novel direct steam stripping process showed potential to reduce regeneration energy in comparison to the conventional regeneration process. The minimum energy consumption of direct steam stripping mode was 2.98 MJ/kg CO 2 , 23% lower than that of the conventional regeneration mode which is 3.88 MJ/kg CO 2 . Water balance was also investigated. Based on the experimental results, a high feeding solvent temperature close to solvent boiling point and superheated carrier steam was preferred for direct steam stripping process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.