Abstract

To assess a machine perfusion system in rescuing liver grafts from non-heart-beating donors (NHBD). The introduction of extracorporeal liver perfusion systems in the clinical routine depends on feasibility. Conceivably, perfusion could be performed during recipient preparation. We investigated whether a novel rat liver machine perfusion applied after in situ ischemia and cold storage can rescue NHBD liver grafts. We induced cardiac arrest in male Brown Norway rats by phrenotomy and ligation of the subcardial aorta. We studied 2 experimental groups: 45 minutes of warm in situ ischemia + 5 hours cold storage versus 45 minutes of warm in situ ischemia + 5 hours cold storage followed by 1 hour hypothermic oxygenated extracorporeal perfusion (HOPE). In both groups, livers were reperfused in a closed sanguineous isolated liver perfusion device for 3 hours at 37 degrees C. To test the benefit of HOPE on survival, we performed orthotopic liver transplantation in both experimental groups. After cold storage and reperfusion, NHBD livers showed necrosis of hepatocytes, increased release of AST, and decreased bile flow. HOPE improved NHBD livers significantly with a reduction of necrosis, less AST release, and increased bile flow. ATP was severely depleted in cold-stored NHBD livers but restored in livers treated by HOPE. After orthotopic liver transplantation, grafts treated by HOPE demonstrated a significant extension on animal survival. We demonstrate a beneficial effect of HOPE by preventing reperfusion injury in a clinically relevant NHBD model.