Abstract

Environmental, mechanical and optical reliability are basic premises for application of PLC optical splitters. According to temperature and humidity cycling experiment, it demonstrated that insertion loss of PLC optical splitter varies with temperature. Compared to performance at room temperature, the maximum insertion loss change of device is 0.472 dB at 75 °C, and 0.486 dB at −40 °C. A three-dimensional finite element model of PLC chip coupled with fiber array was established to study the effects of temperature on insertion loss. The simulation results match experimental results, indicating that misalignment of PLC chip and fiber array is the main reason for insertion loss change. It is significant to consider the influences of global temperature rather than only paying attention to performance at static temperature when we evaluate the reliability of PLC optical splitters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.