Abstract

The Ring-Imaging Cherenkov (RICH) detectors at LHCb have an intrinsic time resolution of better than 10 ps owing to the prompt Cherenkov radiation and focusing mirrors optics. While only spatial information has been used in the experiment to date, the addition of photon time information is one of the cornerstones of the future RICH upgrade programme. The novel timing techniques provide a powerful tool for background suppression and particle ID performance improvements. Here, developments to implement fast-timing in the front-end electronics are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.