Abstract

PurposeThis study developed a novel multi-axial alveolar distractor and evaluated its safety and effectiveness by performing various mechanical tests and finite element (FE) analysis. Materials and methodsA ball-and-socket joint with a high degree of freedom was proposed as the design concept to make the distractor produce a cone trajectory motion range of up to 60° with respect to the transport screw (central axis). This device was manufactured with Ti6Al4V alloy. Mechanical functional tests included four-point bending resistance testing of the base bone plate, pull-out testing of the multi-axial alveolar distractor, welding strength testing between the base bone plate and ball-and-socket joint mechanism, and torque strength testing of the ball-and-socket joint. These tests were performed to ensure the effectiveness and safety of the multi-axial alveolar distractor. The base bone plate FE analysis of four-point bending resistance and pull-out testing of the multi-axial alveolar distractor were performed to confirm the results obtained from the experimental testing. ResultsThe bending strength for the four-point bending test and the maximum force for pull-out testing were 530.88 N mm and 716.33 N, respectively. Substantial equivalence FE simulations also found that large deformations for four-point bending and pull-out testing were smaller than those for the commercial alveolar distractor, indicating that our new distractor is as safe and effective as the commercially available device. The maximum debonding torque resistance for ball-and-socket joint mechanism welding strength was 3481.1 N mm, meaning it is unable to fall off during a surgical operation. No damage was found at the welding edge. The maximum average resistance force in the ball-and-socket joint was 30.26 N without rotation, allowing it to resist distraction forces during bone regeneration — an important safety consideration. ConclusionThe alveolar distractor designed using a ball-and-socket joint concept can achieve multi-axial distraction with various angle adjustments in 3D space. Thorough mechanical/functional tests confirm the effectiveness and safety of our new multi-axial alveolar distractor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.