In this study, a rapid sandwich immunochromatographic assay (ICA) was developed to detect parvalbumin (PV). Firstly, two optimum primary monoclonal antibody (mAb) against PV had been screened out: mAb1 was used as the capture antibody, and mAb2 conjugated to Fe3O4/Au nanoparticles (Fe3O4/AuNPs) that served as a detection reagent. Using this pair of mAbs, a sandwich ICA strip based on Fe3O4/AuNPs was developed. The results showed that the color intensity of test line positively correlated with the PV concentration in the standard or spiked sample. The limit of detection for qualitative (LOD) and quantitative detection (LOQ) were 2 ng/mL and 0.691 ng/mL, respectively. Besides, the detection time of this ICA strip was within 15 min. The recovery rates ranged from 104.0% to 117.4%, within an acceptable level (80–120%). Moreover, the developed assay also showed high cross reaction in different fish species. These results demonstrated that the established test strip has the potential to be used as a rapid screening tool for large scale determination of PV in foodstuffs.