Abstract

AbstractThis paper presents techniques developed to accurately model the characteristics of transformer oil for the purpose of predicting the effect of aging on these characteristics. Aging causes some of the transformer oil characteristics to violate the internationally specified limits. The purpose of this simulation is to develop alternative techniques to predict the operating time after which these characteristics would violate the limits. The results obtained from monitoring of twenty in‐service power transformers for long period of operating time up to ten years have been implemented in developing the proposed models. The physical, chemical and electrical characteristics have been determined periodically by internationally specified testing methods. The patterns of violation sequence of the standard limits, against operating time, by different transformer oil characteristics have been revealed and the most common pattern has been determined. The definition of residual operating time (trot) of the different transformer oil characteristics has been introduced. The choice of transformer oil breakdown voltage trot to represent that of the transformer oil characteristics has been justified. Modelling of trot as a function of transformer oil breakdown voltage, total acidity and water content by multiple‐linear regression has been proposed and verified. Also, polynomial regression model of trot as a function only of transformer oil breakdown voltage has been given. The accuracy and applicability of these models and the different modelling techniques have been discussed and proved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call