Abstract

The paper deals with a new method for a sensitivity analysis in linear hybrid circuits. The circuits in view can contain elements with both lumped and distributed parameters when multiconductor transmission lines (MTL) play the role of their distributed parts. The technique is based on the modified nodal analysis (MNA) method serving to the basic description of the circuit. Firstly the frequency-domain sensitivities formulae are derived then the numerical inversion of Laplace transforms (NILT) is applied to obtain the time-domain sensitivities. In this paper a novel method for evaluation of sensitivities with respect to distributed parameters is elaborated while considering lossy nonuniform multiconductor transmission lines.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.