Abstract

A new glass plate (GP) has been developed for a hole-type micropattern gas detector (MPGD). The material of the GP is a crystallized photosensitive etching glass (PEG3C) made by Hoya Corporation. A basic performance test of the hole-type MPGD was carried out using an X-ray beam with Ne-based gas mixtures at 1atm. Gains of up to 5×103 and 6×104 were obtained using a single and a double GP, respectively. An energy resolution of 17% was obtained for 6keV X-rays with a single GP. It was also shown that there is little charging-up effect in the GP. In this paper, we report the characteristics of the new hole-type MPGD with a GP made of PEG3C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.