Abstract

Novel general expressions are constructed and presented that describe the behavior of the height equivalent of a theoretical plate (plate height), H, as a function of the linear velocity, Vx, along the axis, x, of the column and the kinetic parameters that characterize the mass transfer and adsorption mechanisms in chromatographic columns. Open tube capillaries as well as columns packed with either non-porous or porous particles are studied. The porous particles could have unimodal or bimodal pore-size distributions and intraparticle convective fluid flow and pore diffusion are considered. The expressions for the plate height, H, presented in this work could be applicable to high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) systems, and could be used together with experimental plate height, H, versus linear velocity, Vx, data to determine the values of the parameters that characterize intraparticle convective fluid flow and pore diffusion. Furthermore, chromatographic systems under unretained as well as under retained conditions are examined. The experimental values of the plate height, H, versus the linear velocity, Vx, for a CEC system involving charged porous silica C8 particles and an uncharged analyte are compared with the theoretical results for the plate height, H, obtained from the expressions presented in this work. The agreement between theory and experiment is good, and the results indicate that the magnitude of the intraparticle electroosmotic flow (EOF) in the pores of the particles is substantial while the pore diffusion coefficient was of small magnitude. But the overall intraparticle mass transfer resistance in these particles was low because of the significant contribution of the intraparticle EOF. Simulation results are also presented (i) for a hybrid HPLC-CEC system, and (ii) for different CEC systems involving open capillaries as well as packed columns having non-porous or porous particles. The analysis of the results indicates (a) the reasons for the superior performance exhibited by the hybrid HPLC-CEC system over the performance obtained when the system is operated only in the HPLC mode, and (b) the operational configuration and the properties that the structure of the porous particles would have to have in CEC systems involving uncharged or charged analytes under unretained or retained conditions in order to obtain high CEC efficiency (low values of the plate height, H).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.