Abstract

AbstractNewly synthesized poly(styrene‐g‐oleic amide) was coated onto a rhodium nanoparticle modified glassy carbon (GC) surface for the fabrication of horseradish peroxidase based biosensor used for hydrogen peroxide detection. The rhodium modifed electrode presented ten times higher signal than unmodified electrode even at low elecrtroactive enzyme quantity by enhancing the electron transfer rate at the applied potential of −0.65 V. The biosensor designed by under the optimized rhodium electrodeposition time exhibited a fast response less than 5 s, an excellent operational stability with a relative standard deviation of 0.6 % (n=6), an accuracy of 96 % and a large linear range between 50 μM and 120 mM for hydrogen peroxide. Detection limit and the sensitivity parameters were calculated to be 44 μM and 57 μA mM−1 cm−2, respectively by preserving its entire initial response up to the 15 days, while only 20 % of its initial response was lost at the end of one month.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.