Abstract

Background:Swallowing disturbance is among the most burdensome complications suffered by patients with glossopharyngeal and vagus nerve involvement in lesions adjacent the jugular foramen. For monitoring these nerves, we have developed new devices that comprised four contacts adhering to the surface of the cuff of an endotracheal tube, with attachment the posterior pharyngeal wall. To determine whether these devices are useful for monitoring the glossopharyngeal and vagus nerves and predicting postoperative swallowing dysfunction in patients undergoing removal of skull base tumors involving these nerves.Methods:We studied 10 patients. Compound muscle action potentials (CMAPs) were recorded from the posterior pharyngeal wall by stimulating the glossopharyngeal or vagus nerve in order to identify the nerve course, especially in patients showing severe nerve distortion due to the tumor. Pharyngeal motor evoked potential (PhMEP) elicited by transcranial electrical stimulation were recorded in all patients. The correlation between the final to baseline PhMEP ratio and postoperative swallowing function was examined.Results:Responses were obtained in six of the seven patients in whom CMAP monitoring was performed. Deterioration of swallowing function postoperatively was demonstrated in six of seven (86%) patients with intraoperative PhMEP ratios <50%. None of the three patients with intraoperative PhMEP ratios >50% showed deterioration of swallowing function after surgery, although the one patient already had severe swallowing dysfunction requiring preoperative tracheostomy.Conclusions:Our novel devices were useful for monitoring the glossopharyngeal and vagus nerves in patients undergoing removal of skull base tumors involving these nerves.

Highlights

  • Swallowing disturbance is among the most burdensome complications suffered by patients with glossopharyngeal and vagus nerve involvement in lesions adjacent the jugular foramen

  • Quick Response Code: INTRODUCTION Intraoperative monitoring of swallowing function is important for skull base surgery in patients in whom the glossopharyngeal and vagus nerves are involved in the tumor

  • Surgical Neurology International 2013, 4:97 been monitored using needle electrodes placed in the vocal cords or pharyngeal wall, as well as surface electrodes on an endotracheal tube adhering to the vocal cords.[1,5,6,7,8]

Read more

Summary

Introduction

Swallowing disturbance is among the most burdensome complications suffered by patients with glossopharyngeal and vagus nerve involvement in lesions adjacent the jugular foramen. For monitoring these nerves, we have developed new devices that comprised four contacts adhering to the surface of the cuff of an endotracheal tube, with attachment the posterior pharyngeal wall. We have developed new devices that comprised four contacts adhering to the surface of the cuff of an endotracheal tube, with attachment the posterior pharyngeal wall To determine whether these devices are useful for monitoring the glossopharyngeal and vagus nerves and predicting postoperative swallowing dysfunction in patients undergoing removal of skull base tumors involving these nerves

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.