Abstract

The Hefei Light Source-II (HLS-II) is a vacuum ultraviolet synchrotron light source. The personnel safety system (PSS), which is a personnel access control system, is a crucial part of the HLS-II, as it protects the staff and users at HLS-II from radiation damages. The prior version of HLS-II PSS was based on an access control system called SiPass. This lacked the personnel management function. Meanwhile, as the prior PSS is a turn-key system, it was not effective for sharing information. To overcome these drawbacks, the novel design of PSS for HLS-II is proposed based on the Siemens redundant programmable logic controller under the Experimental Physics and Industrial Control System. The proposed PSS consists of a safety interlock system, access control system, and a radiation monitoring system. The safety interlock system is used to define the interlock logic. The access control system is designed to restrict the access of staff and users at HLS-II, and to provide a personnel management function. The radiation monitoring system is used to monitor the radiation dose rate in both the light source and the surrounding areas. This paper details the architecture and the specific design of the novel PSS. The off-line test results demonstrate that the proposed system has achieved the design objectives.