Abstract

ObjectivesTo validate novel non-contacting Confocal-Laser-Scanning-Microscopy (CLSM) methodology with conventional Contacting Profilometry (CP) measures investigating brushing or dab-on of stannous-fluoride dentifrice on early aggressive dentine erosion.Methods75 polished human dentine samples were prepared and eroded in agitated 6% citric acid then randomly allocated into 5 intervention groups; artificial saliva control (1); controlled use of a pressure sensitive counter-rotating oscillatory powered toothbrush with sodium-fluoride NaF (2) or stannous-fluoride SnF2 (3), and dab-on application of NaF (4) or SnF2 (5). Samples underwent three cycles of intervention and 2-min agitated 6 % citric acid challenges. CLSM images were taken and 3D reconstructions produced of step height using a developed software algorithm. In addition, 20 % samples were randomised and profiled using CP to measure step height and surface roughness. Vickers's diamond micro-hardness testing was carried out on all samples.ResultsComparing CLSM and CP; Pearson correlation was 0.77 and Intra-class correlation 0.81 (p = 0.01). There were no significant statistical differences in step height between groups using both CLSM and CP. From baseline, SnF2 brushing (3) increased micro-hardness more than control (1) (p = 0.03), NaF (4) and SnF2 dab-on (5) (p ≤ 0.001), and increased surface roughness more than control (p = 0.02), NaF brushing (2) and NaF dab-on (4) (p ≤ 0.017). Dab-on of SnF2 (5) produced rougher surfaces than control (1) (p = 0.014) and reduced hardness compared with NaF brushing (p = 0.04).ConclusionsGood agreement and correlation exists between CLSM and CP measures in dentine. There were no significant differences in surface loss after interventions between groups. Compared with control, SnF2 application increased dentine surface roughness and SnF2 controlled powered brushing application increased dentine hardness, likely caused by exposure of uneroded dentine.Clinical significanceIsosurfaces produced using CLSM can be used to represent dentine step height loss. They show good correlation and agreement with conventional CP measures, following early aggressive erosion-abrasion cycles of dentine. The CLSM and computer algorithm therefore provides an accurate, standalone and non-contacting three-dimensional measurement of early dentine wear. Stannous-fluoride brushing, and dab-on application offer no benefits following early aggressive erosion in dentine. To reduce dentine wear, limiting erosive challenges and avoiding brushing post-erosion is advised.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.