Abstract

The potential route of contamination by skin microorganisms onto the distal tip of central venous catheters during insertion was investigated. Thirty patients undergoing cardiac surgery who required a central venous catheter (CVC) as part of their clinical management were studied. Following catheter placement, the device insertion equipment and the skin at the insertion site were sampled for microorganisms. The distal tips of the CVCs were also sampled in situ within 90 min post insertion. Bacteria were isolated from 20 of 30 (66%) CVC skin insertion sites, from 15 of 30 (50%) guidewires, and from five of 30 (16%) catheter distal tips in situ. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted during insertion onto the distal tip of the CVC, which may act as a subsequent nidus of infection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.