Abstract

In this paper, a novel amperometric xanthine (X) biosensor is constructed by xanthine oxidase (XOx) immobilization on the pencil graphite electrode (PGE). Xanthine oxidase is immobilized using glutaraldehyde (GA) on the electrochemically polymerized conducting polymer film. The detection of xanthine is based on its consumed amount due to the enzymatic reaction of xanthine oxidase. The effects of polymer thickness, applied potential, pH, and temperature were investigated and optimum parameters were found to be five cycles, +5V, +0.5V and 30°C, respectively. Storage stability, operation stability of the enzyme electrode, and effect of interferant substances on the amperometric response were also studied. In order to verify the applicability of proposed biosensor, fabricated electrode was used to measure the xanthine concentration in chicken meat samples. The present xanthine biosensor with high selectivity, sensitivity, and stability is promising for practical applications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.