Abstract
A method is presented for the cancellation of wide band contaminating noise occurring within internal flow configurations such as rectangular channels and pipes. Facility generated noise within these flow systems contaminates the turbulent wall pressure signature at low frequencies thus preventing the possible extraction of useful information. The proposed methodology utilizes the signals from two flush mounted wall pressure transducers. A first estimate for the one-point spectral density is obtained using a least mean square algorithm. A secondary correction to this estimate is obtained by taking advantage of the planar homogeneity of the turbulence. The application of the technique is demonstrated in a fully developed turbulent channel flow for which a more than 40 dB cancellation is obtained at low frequencies. In this low frequency range, the power spectral density is shown to have an approximate quadratic dependence, substantiating past theoretical predictions reported in the literature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.