Abstract
Based on the Littrow and Littman configurations for autocollimation, two methods are proposed herein with a fore-end light path comprising fused fiber couplers and fiber port collimators to measure the diffraction grating period. The experimental data from a uniform-line-spacing grating with a nominal value of 1200 lines/mm agreed well with theoretical values and with measurement errors of the Littrow and the Littman configurations of 1.05 × 10-4 and 4.99 × 10-5, respectively. Both methods were demonstrated to reduce the diameter of the laser spot and improve the alignment precision of the measurement system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.