Abstract
We present an efficient in situ sampling device that allows a simple and quantitative sampling of natural periphyton communities. The Brush Sampler is based on a previously developed sampler, which was improved by the addition of an external water supply, ball valve closing mechanism, and special exchangeable stiff brushes to solve previously reported problems of biomass overestimation and underestimation. The Brush Sampler was tested under ambient conditions in the field at four different sampling sites in a lentic and a lotic system and compared to the old sampler and control samples. The tests revealed a high inaccuracy of the old sampler and showed that biomass estimates (ash-free dry mass and chlorophyll-a content) obtained with the improved Brush Sampler did not significantly differ from biomass values determined from scrapings of control samples collected at the same sites. Therefore, our modified sampling device can be used as a tool for quantitative and qualitative epilithon community analyses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.