Abstract

During a 6-month period, two genetically distinct clones were isolated from 65% of patients with Pseudomonas aeruginosa isolated from bronchial specimens obtained during or after bronchoscopy. This epidemic was due to contamination of bronchoscopes by washing machines. After reintroduction of manual disinfection of endoscopes, a significant decrease in the incidence of the epidemic clones was observed, but the incidence of nonepidemic P aeruginosa did not change. The distinction between sporadic and epidemic cases was possible only with the use of a molecular typing method (ribotyping).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.