Abstract

Background:Despite the usefulness of ulnar nerve conduction studies in identifying disorders of ulnar nerves, there is a lack of normative values for the ulnar nerve in Nigerian population.Objective:The objective of the study was to generate normative values for motor and sensory ulnar nerve conduction studies (NCSs) in Nigerian population and to determine the influence of gender and height on ulnar nerve conduction velocity (NCV).Materials and Methods:A total of 200 healthy volunteers were selected after clinical evaluation to exclude common causes of ulnar neuropathy. We carried out NCS of ulnar nerves on all the healthy volunteers according to a standardized protocol. The NCS parameters included in the final analysis were amplitude, latency, NCV, and f-wave latency. Ethical approval was obtained for the study.Results:The mean ulnar nerve sensory velocity was 55.22 ± 5.67 with 2.5 and 97.5 percentile of 46.9 and 70.1, respectively. The mean latency of the ulnar nerve (sensory) was 2.97 ± 0.62 with 2.5 and 97.5 percentile of 2.00 and 4.52, respectively. The mean amplitude of the ulnar nerve (sensory) was 35.56 ± 9.97 with 2.5 and 97.5 percentile of 15.9 and 57.7, respectively). The ulnar NCV was significantly (P = 0.0202) higher in male. Mild inverse correlation (r = 0.2) was found between ulnar NCV and height of the participants (P = 0.0089).Conclusion:In the Nigerian population, normative values of motor and sensory ulnar nerve conduction parameters are similar to the existing values in the literature. The ulnar NCV appeared to be influenced by height and gender.