Abstract
Prior to large studies in breast cancer patients, we have sought to establish the normal range of a potential serum biomarker, Amphiregulin, in healthy women and to determine whether sampling during the menstrual cycle influences the detected Amphiregulin levels. Serum Amphiregulin levels were quantified using a commercially available ELISA in 85 normal female donors. The range of circulating Amphiregulin was 0-4467 pg/mL. The majority of women had no detectable circulating Amphiregulin (n=54), and only five women had levels exceeding 500 pg/mL. Serum Amphiregulin levels did not vary significantly during the menstrual cycle (n=7 women). Detection of circulating Amphiregulin in a significant minority of healthy women suggests that it may not have the specificity necessary for a population screening tool; however its potential utility for monitoring response to treatment or disease progression should be examined in breast cancer cases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.