Abstract

Compute tomography anatomy of the orbits is well described, but only a few reports are available on normal measurements of the extraocular muscles (EOM) and globe position (GP). We obtained CT images from patients who were referred to our department for CT of the paranasal sinuses using a standard protocol for evaluation of normal orbital measurements. Our study suggests that optimum results are attained with the use of a coronal scan at a window level and width setting that results in an optimum image at the maximum muscle width for assessment of EOM and an axial scan at the mid-GP for GP and interzygomatic line. Based on our normal values, a right-to-left ratio of more than 1.4 for EOM diameter or 1.2 for GP is indicative of asymmetry. An absolute diameter of EOM > 8 mm and GP < 2 mm are abnormal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.