Abstract
This paper presents the normal force phenomena for static and steady shear mode in magnetorheological (MR) fluid. The results of the study show that, in the static mode, with the magnetic flux density increasing, the normal force will increase until the maximum, and then reduce to a steady value, and during the increasing stage, it can be expressed as FN=4667*B2.48 approximately; however, in the steady shear mode, only when the magnetic flux density achieves a certain value, the normal force phenomena will be observed clearly, and with the increasing of magnetic field, the normal force reaches the maximum, and then also decreases to a steady value. Besides, by defining the time parameters of dynamic response, the dynamic response of normal force is studied. If the shear plate is stationary, from the magnetic field on to a stable normal force produced, the response time is about 25.11ms.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.