Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> This paper presents an approach to improve dynamic responses of digitally controlled dc–dc converters using nonuniform analog-to-digital (A/D) quantization of the output voltage error. The nonuniform A/D quantizer parameters are selected to achieve improved step-load transient responses without compromising stability margins. The implementation, which includes a programmable A/D quantizer and a look-up table based discrete-time compensator, is simple and well suited for practical high-frequency digital pulsewidth modulation controllers. Simulation and experimental results are presented for a proof-of-concept point-of-load 5 V-to-1.3 V digitally controlled synchronous buck converter. </para>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.