Abstract

A two-dimensional numerical analysis of the cross section of a homopolar inductor alternator supplying a rectifier load is developed. Besides the effects of the nonlinearities of the magnetic materials, the eddy currents induced in the rotor by the nonlinear load are considered. Results for a 95-kVA homopolar inductor alternator are presented and include magnetic induction and flux distribution at two instants of time, output voltage, eddy current densities, and loss. The theoretical results have been found to be in good agreement with available test data on the alternator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.