A new approach to time-frequency transform and pattern recognition of non-stationary power signals is presented in this paper. In the proposed work visual localization, detection and classification of non-stationary power signals are achieved using hyperbolic S-transform known as HS-transform and automatic pattern recognition is carried out using GA based Fuzzy C-means algorithm. Time-frequency analysis and feature extraction from the non-stationary power signals are done by HS-transform. Various non-stationary power signal waveforms are processed through HS-transform with hyperbolic window to generate time-frequency contours for extracting relevant features for pattern classification. The extracted features are clustered using Fuzzy C-means algorithm and finally the algorithm is optimized using genetic algorithm to refine the cluster centers. The average classification accuracy of the disturbances is 93.25% and 95.75% using Fuzzy C-means and genetic based Fuzzy C-means algorithm, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.