Abstract
Currently, CEN TC/250 completes the development of a new generation of Structural Eurocodes. In accordance with the strategy declared in Mandate M/515 EN, each Eurocode should contain special requirements related to the assessment and retrofitting of existing structures. The characteristic in-situ concrete strength can be statistically determined based on test results. According to draft EN 13791, the 5-th-percentile value can be calculated based on a unilaterally limited constant of 75% confidence level. Sometimes, estimation of the characteristic in-situ concrete strength based on a constant confidence level does not allow for an adequate reliability assessment of existing structures. Therefore a new estimator based on non-parametric statistics has been proposed for estimating the in-situ characteristic concrete strength with a given arbitrary confidence level. It was found that the choice of confidence level estimation should be based on the average level of structural reliability (ALSR).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.