Abstract
We present results from four independent models of a granular assembly subjected to tapping. We find that the steady-state packing fraction as a function of the tapping intensity is nonmonotonic. In particular, for high tapping intensities, we observe an increase of the packing fraction with tapping strength. This finding challenges the current understanding of compaction of granular media since the steady-state packing fraction is believed to decrease monotonically with increasing tapping intensity. We propose an explanation of our results based on the properties of the arches formed by the particles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.