Abstract

To assess the alterations in human donor corneal tissue induced by Q-switched erbium (Er):YAG laser corneal trephination. Thirty human corneoscleral donor buttons unsuitable for transplantation were placed in an artificial chamber on an automated rotation device. Corneas were trephined with a Q-switched Er:YAG laser (wavelength, 2.94 microm; pulse duration, 400 nanoseconds) along (donor and recipient) aluminum silicate (ceramic) open masks. A spot diameter of 0.65 mm, energy setting of 50 mJ/pulse, and repetition rate of 5 Hz were used. Corneal thermal damage and cut regularity were quantitatively assessed in 24 corneas processed for light microscopy and by transmission and scanning electron microscopy. The stromal thermal damage was the highest (mean [SD], 8.0 [2.7] microm) at a 150-microm cut depth and decreased downward. Cut regularity was very good and did not significantly differ between donors and recipients. Scanning electron microscopy confirmed that the cuts were highly regular; transmission electron microscopy revealed 2 distinctive subzones within the stromal thermal damage zone. Thermal damage induced by Q-switched Er:YAG nonmechanical corneal trephination was low, and the regularity of the cuts was very good. The Q-switched Er:YAG laser may have the potential to become an alternative to the excimer laser for nonmechanical penetrating keratoplasty.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.