Abstract

The LEP Spectrometer determines the energy of the beam by measuring the bending angle due to a dipole magnet, using a total of six beam position monitors (BPM). The response to an off-centre beam of a BPM is not strictly linear with displacement and, in addition, depends on the size of the beam. The response also depends on the shape of the aperture of the BPM itself, since the inner surface is conducting and must therefore be an equipotential. For the LEP Spectrometer, BPM nonlinearities may become large enough to affect the beam energy measurement. We calculate the size of the effect for Gaussian beams within circular and elliptical apertures, drawing conclusions regarding the operation of the Spectrometer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.