Abstract

This paper deals with the nonlinear analytical harmonic modeling (HM) of three phases, and 6/4 conventional switched reluctance machine (SRM). The proposed model consists in computing magnetic field distribution and electromagnetic performances of an SRM with conventional winding. Because an SRM has inherently nonlinear characteristics, the analytical subdomain model that does not take into account the saturation has a limited accuracy. This is due to the assumption of infinite tooth permeability. The new analytical model (AM) based on the HM technique, which overcomes this limitation, is presented with the consideration of the local magnetic saturation on the stator and rotor teeth. The results obtained with the nonlinear AM have been compared with the linear AM based on the subdomain method (i.e., without the saturation effect) and nonlinear finite-element method solutions.