Abstract

Nonisothermal stability tests have been proposed as an attractive and alternative method to the conventional isothermal stability tests. The stability and the degradation properties of famotidine and nizatidine were investigated using both isothermal and nonisothermal stability test techniques. Linear and logarithmic temperature programs were used and the degradation rate constant and activation energies were calculated using a computer program, which was written in basic. Also the advantages and disadvantages of these temperature programs are compared. The method to estimate parameters is based on nonlinear curve fitting the nonisothermal concentration–time–temperature curve equation. The nonisothermal stability test results were compared with the results of isothermal stability tests and similar results were obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.