Abstract

To evaluate whether hypercapnic acidosis attenuates acute alterations of pulmonary capillary permeability due to high lung stretch in rats using a simple, noninvasive, scintigraphic method. Prospective, randomized, controlled animal study. University research laboratory. Male adult Wistar rats weighing 291 +/- 7.5 g. Three groups of rats were studied: controls ventilated with a low (6 mL/kg body weight) tidal volume and rats ventilated with a high (38 mL/kg body weight) tidal volume under normocapnic (Paco(2) = 35.2 +/- 1.65 mm Hg) or hypercapnic (Paco(2) = 102.5 +/- 5.63 mm Hg) conditions. Pulmonary capillary permeability alterations were assessed by monitoring the rate of (111)In-transferrin accumulation in lung tissue. Respiratory system pressure-volume curves were registered and analyzed. High tidal volume ventilation increased In-transferrin plasma to lung flux in such a way that I(111)In-transferrin behaved like a marker of water. The rate of initial (first 30 mins of high tidal volume ventilation) lung transferrin accumulation measured by scintigraphy (standardized lung/heart ratio) was steady, correlated with the percent decrease in respiratory system compliance (a marker of edema progression), and did not differ between normocapnic and hypercapnic groups (18.9 +/- 3.97 vs. 14.2 +/- 2.89%/hr, not significant). However, lung In-tranferrin accumulation rate was highly scattered due to variable interindividual mechanical properties of the respiratory system. This rate was correlated with initial values of volume of the upper inflection point of the pressure-volume curve (r = -.53, p < .001) and end-inspiratory pressure (r = .54, p < .001). Mechanical properties were similar in normocapnic and hypercapnic rats. There was no difference between In-transferrin accumulation rates in these rats when a stringent selection was made based on end-inspiratory pressure (28-32 cm H(2)O) or body weight (330-360 g). Hypercapnic acidosis does not influence in vivo the acute increase in pulmonary capillary permeability due to high-volume ventilation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.