Abstract

A noninvasive method for glomerular filtration rate-determination, in which the use of radioactive tracers and sampling of plasma and urine can be omitted, is described. After injection of iodinated contrast material in rabbits, the iodine content of tissue, serum, and urine is measured by means of x-ray fluorescence analysis. The disappearance rates of iodine in tissue and serum are found to be the same, and a strong correlation is found between clearance values calculated from serum and tissue measurements. This indicates the possibility of evaluating kidney function by x-ray fluorescence analysis of contrast material in tissue only.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.