Abstract

We sought to evaluate a multiplexed massively parallel shotgun sequencing assay for noninvasive trisomy 21 detection using circulating cell-free fetal DNA. Sample multiplexing and cost-optimized reagents were evaluated as improvements to a noninvasive fetal trisomy 21 detection assay. A total of 480 plasma samples from high-risk pregnant women were employed. In all, 480 prospectively collected samples were obtained from our third-party storage site; 13 of these were removed due to insufficient quantity or quality. Eighteen samples failed prespecified assay quality control parameters. In all, 449 samples remained: 39 trisomy 21 samples were correctly classified; 1 sample was misclassified as trisomy 21. The overall classification showed 100% sensitivity (95% confidence interval, 89-100%) and 99.7% specificity (95% confidence interval, 98.5-99.9%). Extending the scope of previous reports, this study demonstrates that plasma DNA sequencing is a viable method for noninvasive detection of fetal trisomy 21 and warrants clinical validation in a larger multicenter study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.