Abstract

BackgroundTo assess the clinical validity of controlled attenuation parameter (CAP) in the diagnosis of hepatic steatosis in a series of overweight or obese children by using the imperfect gold standard methodology.MethodsConsecutive children referred to our institution for auxological evaluation or obesity or minor elective surgery were prospectively enrolled. Anthropometric and biochemical parameters were recorded. Ultrasound (US) assessment of steatosis was carried out using ultrasound systems. CAP was obtained with the FibroScan 502 Touch device (Echosens, Paris, France). Pearson’s or Spearman’s rank correlation coefficient were used to test the association between two study variables. Optimal cutoff of CAP for detecting steatosis was 249 dB/m. The diagnostic performance of dichotomized CAP, US, body mass indexes (BMI), fatty liver index (FLI) and hepatic steatosis index (HSI) was analyzed using the imperfect gold standard methodology.ResultsThree hundred five pediatric patients were enrolled. The data of both US and CAP were available for 289 children. Steatosis was detected in 50/289 (17.3%) children by US and in 77/289 (26.6%) by CAP. A moderate to good correlation was detected between CAP and BMI (r = 0.53), FLI (r = 0.55) and HSI (r = 0.56). In obese children a moderate to good correlation between CAP and insulin levels (r = 0.54) and HOMA-IR (r = 0.54) was also found. Dichotomized CAP showed a performance of 0.70 (sensitivity, 0.72 [0.64–0.79]; specificity, 0.98 [0.97–0.98], which was better than that of US (performance, 0.37; sensitivity, 0.46 [0.42–0.50]; specificity, 0.91 [0.89–0.92]), BMI (performance, 0.22; sensitivity, 0.75 [0.73–0.77]; specificity, 0.57 [0.55–0.60]) and FLI or HSI.ConclusionsFor the evaluation of liver steatosis in children CAP performs better than US, which is the most widely used imaging technique for screening patients with a suspicion of liver steatosis. A cutoff value of CAP of 249 dB/m rules in liver steatosis with a very high specificity.

Highlights

  • To assess the clinical validity of controlled attenuation parameter (CAP) in the diagnosis of hepatic steatosis in a series of overweight or obese children by using the imperfect gold standard methodology

  • Controlled attenuation parameter (CAP) is a method for the non-invasive assessment of liver steatosis. It measures the attenuation of the ultrasound beam that traverses the liver tissue, which increases in fatty liver, and is obtained by analyzing the ultrasound signal acquired by the transient elastography device (Fibroscan 502 Touch, Echosens, Paris, France) [6]

  • Overall 305 pediatric patients were enrolled of whom 199 (103 males, 96 females; mean age, 11.5 years ([standard deviation (SD): 2.7]; range, 4.1–17.4) were referred for auxological evaluation or obesity and 106 (64 males, 42 females; mean age, 9.9 [SD: 3.3 years] for minor elective surgery. 100/199 (50.3%) children referred for auxological evaluation or obesity were overweight (54 males, 46 females; mean age, 11.7 [SD: 2.6] years) and 99/199 (49.7%) children were obese (50 males, 49 females; mean age, 11.0 [SD: 2.9] years)

Read more

Summary

Introduction

To assess the clinical validity of controlled attenuation parameter (CAP) in the diagnosis of hepatic steatosis in a series of overweight or obese children by using the imperfect gold standard methodology. Controlled attenuation parameter (CAP) is a method for the non-invasive assessment of liver steatosis. It measures the attenuation of the ultrasound beam that traverses the liver tissue, which increases in fatty liver, and is obtained by analyzing the ultrasound signal acquired by the transient elastography device (Fibroscan 502 Touch, Echosens, Paris, France) [6]. It has been shown that CAP has a good accuracy for quantifying liver steatosis in pediatric patients [7]

Objectives
Methods
Results
Discussion
Conclusion