Abstract

BackgroundPulsus paradoxus estimated by dynamic change in area under the oximeter plethysmograph waveform (PEP) might provide a measure of acute asthma severity. Our primary objective was to determine how well PEP correlates with forced expiratory volume in 1-second (%FEV1) (criterion validity) and change of %FEV1 (responsiveness) during treatment in pediatric patients with acute asthma exacerbations.MethodsWe prospectively studied subjects 5 to 17 years of age with asthma exacerbations. PEP, %FEV1, airway resistance and accessory muscle use were recorded at baseline and at 2 and 4 hours after initiation of corticosteroid and bronchodilator treatments. Statistical associations were tested with Pearson or Spearman rank correlations, logistic regression using generalized estimating equations, or Wilcoxon rank sum tests.ResultsWe studied 219 subjects (median age 9 years; male 62%; African-American 56%). Correlation of PEP with %FEV1 demonstrated criterion validity (r = - 0.44, 95% confidence interval [CI], - 0.56 to - 0.30) and responsiveness at 2 hours (r = - 0.31, 95% CI, - 0.50 to - 0.09) and 4 hours (r = - 0.38, 95% CI, - 0.62 to - 0.07). PEP also correlated with airway resistance at baseline (r = 0.28 for ages 5 to 10; r = 0.45 for ages 10 to 17), but not with change over time. PEP was associated with accessory muscle use (OR 1.16, 95% CI, 1.11 to 1.21, P < 0.0001).ConclusionsPEP demonstrates criterion validity and responsiveness in correlations with %FEV1. PEP correlates with airway resistance at baseline and is associated with accessory muscle use at baseline and at 2 and 4 hours after initiation of treatment. Incorporation of this technology into contemporary pulse oximeters may provide clinicians improved parameters with which to make clinical assessments of asthma severity and response to treatment, particularly in patients who cannot perform spirometry because of young age or severity of illness. It might also allow for earlier recognition and improved management of other disorders leading to elevated pulsus paradoxus.

Highlights

  • Pulsus paradoxus estimated by dynamic change in area under the oximeter plethysmograph waveform (PEP) might provide a measure of acute asthma severity

  • Sample size We considered a correlation coefficient of 0.30 or greater to be clinically relevant based on the study of Wright and colleagues in which measurement of pulsus paradoxus (PP) calculated from change in height of finger arterial pressure monitor waveforms was correlated with %PEF (r = - 0.31)[36]

  • Associations with outcome measures The correlations between PEP and %FEV1 and airway resistance are included in table 3 and are displayed graphically in figure 3

Read more

Summary

Introduction

Pulsus paradoxus estimated by dynamic change in area under the oximeter plethysmograph waveform (PEP) might provide a measure of acute asthma severity. Our primary objective was to determine how well PEP correlates with forced expiratory volume in 1-second (%FEV1) (criterion validity) and change of %FEV1 (responsiveness) during treatment in pediatric patients with acute asthma exacerbations. Spirometry is the criterion standard for assessing the severity of airway obstruction (% predicted FEV1, %FEV1) but is effort dependent and not available in most acute care settings[8,9]. Airway resistance is another measure of lung function. Rint has been demonstrated to correlate with %FEV1 and specific airway resistance by body box plethysmography[10,11,12,13]

Methods
Results
Discussion
Conclusion